Dodge Journey: Inspection, adjustments

INSPECTION

Inspect the exhaust pipes, catalytic converters, muffler, and resonators for cracked joints, broken welds and corrosion damage that would result in a leaking exhaust system. Inspect the clamps, support brackets, and insulators for cracks and corrosion damage.

ADJUSTMENTS

A misaligned exhaust system is usually indicated by a vibration, rattling noise, or binding of exhaust system components. These noises are sometimes hard to distinguish from other chassis noises. Inspect exhaust system for broken or loose clamps, heat shields, isolators, and brackets. Replace or tighten as necessary. It is important that exhaust system clearances and alignment be maintained.

Perform the following procedures to align the exhaust system:

1. Loosen clamps and support brackets.

2. Align the exhaust system starting at the front, working rearward.

3. Tighten all clamps and brackets once alignment and clearances are achieved.

SPECIFICATIONS

TORQUE

SPECIAL TOOLS

EXHAUST SYSTEM

Exhaust System
Fig. 3: Exhaust Cone Tool - 8404-ECT

Exhaust System
Fig. 4: Back Pressure Test Adapter - CH8519

Exhaust System
Fig. 5: Pressure Transducer CH7063

    Diagnosis and testing
    EXCESSIVE EXHAUST SYSTEM NOISE CONDITION POSSIBLE CAUSES CORRECTION EXCESSIVE EXHAUST NOISE (UNDER HOOD) 1. Exhaust manifold cracked or broken.2. Manifold to cyl ...

    Converter, catalytic
    DESCRIPTION WARNING: The normal operating temperature of the exhaust system is very high. Therefore, never work around or attempt to service any part of the exhaust system until it ...

    See also:

    Description, Operation
    DESCRIPTION Fig. 313: Identifying Differential Assembly - DIFFERENTIAL CASE - RING GEAR - TRANSFER SHAFT - PINION GEAR - PINION SHAFT - SIDE GEAR The 41TE differential is a convent ...

    Installation
    NOTE: LHD model shown in illustrations. RHD model similar. RIGHT FRONT FLOOR DUCT Fig. 71: Duct-Right Front Floor PM NOTE: Illustration shown with instrument panel removed for clarity. ...

    Removal
    WARNING: Review safety precautions and warnings in this part before performing this procedure. See Heating and Air Conditioning/Plumbing - Warning and. Failure to follow the warnin ...